Compatibility chart (further cameras on inquiry):
Have a look to the overview of supported operating systems, cameras and microEnable models.
Framegrabber of SILICONSOFTWARE are optimized on the maximum performances and special featuers of the cameras. At a large number of cameras, the dual mode, the maximum resolution and maximum frame rate are supported . Besides camera specific properties, additional filter or pre-processing operations are supported at most cameras in real time: i.e. 1D or 2D shading correction, colour representation by Bayer correction or "fixed pattern noise" suppression for CMOS sensors.
In the special cases, ask directly about the support for your individual sytem configuration.
 |
microEnable III/IV product line |
 |
microEnable II product line |
 |
microEnable I product line |
Overview
 |
microEnable III / IV |
|
|
 |
Camera interfaces |
overview of supported interfaces to camera types |
|
 |
Camera support |
overview of supported CameraLink camera models |
|
 |
Camera support |
overview of supported GigE Vision camera models |
|
 |
MV Software |
overview of supported Machine Vision software |
|
 |
Operation systems |
recommendations for supported operation systems (OS) |
Camera interfaces
 |
 |
 |
 |
 |
Product Compatibility |
Remark |
|
CameraLink |
Power over CL |
GigE Vision |
GenICam |
|
|
| microEnable III |
x |
|
|
|
|
85 MHz, 1 or 2 BASE |
| microEnable III-XXL |
x |
|
|
|
|
85 MHz, 1 or 2 BASE or 1 MEDIUM |
Products (RReOrganisation)
| New Products (Re-Organisation) |
CameraLink |
Power over CL |
GigE Vision |
GenICam |
formerly
|
| microEnable IV AS1-PoCL |
x |
x |
|
|
|
85 MHz, 1 BASE |
| microEnable IV AD1-CL |
x |
|
|
|
microEnable IV-BASE x1 |
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV AD1-PoCL |
x |
x |
|
|
microEnable IV-BASE x1 PoCL |
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV AD1-mPoCL |
x |
x |
|
|
microEnable IV-BASE x1 miniPoCL |
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV AD4-CL |
x |
|
|
|
|
85 MHz, 1 or 2 BASE,1 MEDIUM or 1 FULL |
| microEnable IV AQ4-GE |
|
|
x |
x |
|
4 GigE Vision cameras |
| microEnable IV VD1-CL |
x |
|
|
|
microEnable IV-FULL x1 |
85 MHz, 1 or 2 BASE,1 MEDIUM or 1 FULL |
| microEnable IV VD4-CL |
x |
|
|
|
microEnable IV-FULL x4 |
85 MHz, 1 or 2 BASE,1 MEDIUM or 1 FULL |
microEnable IV VQ4-GE |
|
|
x |
x |
microEnable IV-GigE x4 |
4 GigE Vision cameras |
Former Products |
CameraLink |
Power over CL |
GigE Vision |
GenICam |
|
|
| microEnable IV-BASE x1 |
x |
|
|
|
|
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV-BASE x1 miniPoCL |
x |
x |
|
|
|
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV-BASE x1 PoCL |
x |
x |
|
|
|
85 MHz, 1 or 2 BASE or 1 MEDIUM |
| microEnable IV-FULL x1 |
x |
|
|
|
|
85 MHz, 1 or 2 BASE, 1 MEDIUM or 1 FULL |
| microEnable IV-FULL x4 |
x |
|
|
|
|
85 MHz, 1 or 2 BASE, 1 MEDIUM or 1 FULL |
| microEnable IV-GigE x4 |
|
|
x |
x |
|
4 GigE Vision cameras |
CameraLink camera support
Camera compatibility chart (selection of tested cameras) |
|
Area cameras
|
|
.
|
Company |
Model |
Single
|
Dual
|
Grey
|
Bayer
|
RGB
|
Remark
|
|
|
Adimec
|
1000m
|
|
|
|
.
|
.
|
.
|
|
.
|
.
|
1600m
|
|
|
|
.
|
.
|
.
|
|
.
|
.
|
4000m
|
|
|
|
.
|
.
|
.
|
|
|
Basler
|
A102k
|
|
|
|
.
|
.
|
.
|
|
.
|
.
|
A202k
|
|
|
|
.
|
.
|
.
|
| . |
. |
A403k |
|
.
|
|
. |
. |
MEDIUM Configuration |
|
.
|
.
|
A501k
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
A501kc
|
|
|
.
|
|
. |
. |
|
|
Dalsa
|
1M28-SA
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
1M75-SA
|
|
|
|
. |
. |
. |
|
.
|
.
|
1M150-SA
|
|
.
|
|
.
|
.
|
. 1M150-SA only in single mode
|
|
.
|
. |
2M30-SA
|
|
|
. |
. |
. |
. |
|
|
e2v
|
Camelia M1
|
|
.
|
|
.
|
.
|
.
|
| . |
. |
Camelia C1
|
|
. |
. |
|
. |
. |
 |
Ikegami |
SKC-145T2
|
|
|
|
. |
. |
. |
 |
IMS |
HDRC models
|
|
|
|
. |
. |
. |
|
|
JAI
|
CV-A70 CL
|
|
|
.
|
.
|
.
|
..
|
| . |
. |
CV-M2 CL
|
|
|
.
|
. |
. |
. |
|
.
|
.
|
CV-M4+ CL
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
CV-M7+ CL
|
|
|
. |
|
. |
. |
|
|
JAI Pulnix
|
TM-1020 CL
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
TM-1320 CL
|
|
|
|
. |
. |
. |
|
.
|
.
|
TM-2016 CL
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
TM-2020 CL
|
|
|
|
. |
. |
. |
|
.
|
.
|
TM-4000 CL
|
|
.
|
|
.
|
.
|
.
|
|
.
|
. |
TM-6710 CL
|
|
|
|
. |
. |
. |
|
.
|
.
|
TM-6760 CL
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
TMC-1000 CL
|
|
|
. |
. |
|
RGB output (integrated Bayer correction)
|
|
.
|
.
|
TMC-6700 CL
|
|
|
.
|
.
|
|
RGB output (integrated Bayer correction)
|
|
|
Kappa |
PS 40 series |
|
|
|
|
|
RGB output (integrated Bayer correction) |
|
.
|
.
|
DX 40 series |
|
|
|
|
|
RGB output (integrated Bayer correction) |
|
.
|
. |
PS 4 series |
|
|
|
. |
. |
. |
|
.
|
.
|
DX 4 series |
|
|
|
.
|
.
|
.
|
 |
Mikrotron |
EoSense |
|
|
|
|
. |
BASE Configuration |
|
.
|
.
|
EoSense / MC136x |
|
.
|
|
.
|
.
|
FULL Configuration |
|
.
|
. |
MC130x |
|
|
|
|
. |
BASE Configuration |
|
.
|
.
|
MC131x |
|
.
|
|
.
|
.
|
FULL Configuration |
 |
Optronis |
CL600x2 |
|
|
|
|
. |
FULL Configuration |
 |
PCO Imaging |
pco.1600/pco.1600s
|
|
|
|
. |
. |
. |
|
.
|
.
|
pco.2000/pco.2000s |
|
|
|
.
|
.
|
.
|
|
.
|
. |
pco.4000/pco.4000s |
|
|
|
. |
. |
. |
|
.
|
.
|
pco.1200hs/pco.1200s |
|
|
|
.
|
.
|
FULL Configuration sensor |
|
|
PhotonFocus
|
MV-D1024 CL series
|
|
|
|
. |
. |
|
|
.
|
.
|
MV-D1024x128 CL series
|
|
|
|
.
|
.
|
.
|
| . |
. |
MV-D1024 TrackCam
|
|
.
|
|
. |
. |
. |
|
.
|
.
|
MV-D752 CL series
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
MV-D640 CL series
|
|
|
|
. |
. |
. |
|
.
|
.
|
MV-D640(C) CL series
|
|
|
.
|
|
.
|
.
|
| . |
. |
Blizzard-60
|
|
.
|
|
. |
. |
. |
|
.
|
.
|
Hurricane-40CL
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
Hurricane-60CL
|
|
|
|
. |
. |
. |
|
.
|
.
|
Thunder-90CL
|
|
|
.
|
.
|
.
|
.
|
 |
Sentech |
STC-CL1500
|
|
|
|
. |
. |
. |
 |
Sick IVP |
IVP Ranger 55
|
|
.
|
|
. |
. |
. |
 |
Sony |
XCL-V500
|
|
|
|
. |
. |
. |
| . |
. |
XCL -700
|
|
|
|
.
|
.
|
. |
| . |
. |
XCL-U1000
|
|
|
|
. |
. |
. |
| . |
. |
XCL-U1000C
|
|
|
.
|
.
|
|
integrated Bayer-RGB conversion |
 |
SVS Vistek
|
SVS 205
|
|
|
|
|
. |
. |
| . |
. |
SVS 4020
|
|
|
|
|
.
|
. |
| . |
. |
SVS 4021CFCP
|
|
|
|
|
. |
. |
| . |
. |
SVS 16000
|
|
|
|
|
.
|
. |
|
|
Toshiba-Teli
|
CSB1100CL
|
|
.
|
|
. |
. |
. |
| . |
. |
CSB4000CL
|
|
.
|
|
.
|
.
|
. |
| . |
. |
CSC12M25BMP19
|
|
.
|
|
. |
. |
.FULL Configuration |
|
Line camera
|
| . |
Company |
Model |
Single
|
Dual
|
Grey
|
Bayer
|
RGB
|
Remark
|
|
|
Basler
|
L101k-1k/2k
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
L103k-1k/2k
|
|
|
|
. |
. |
. |
|
.
|
.
|
L104k-1k/2k
|
|
|
|
.
|
.
|
.
|
|
.
|
. |
L301k
|
|
|
|
. |
. |
. |
|
.
|
.
|
L301kc
|
|
|
.
|
.
|
|
.
|
|
|
Dalsa
|
Piranha series
|
|
|
|
. |
. |
. |
|
.
|
.
|
Piranha 2 series
|
|
.
|
|
.
|
.
|
BASE and MEDIUM
|
|
|
e2v
|
Aviiva series
|
|
|
|
. |
. |
. |
|
.
|
.
|
Aviiva C2 / SC2
|
|
|
.
|
.
|
|
.
|
|
.
|
. |
Aviiva M2 / SM2
|
 |
 |
|
. |
. |
. |
|
.
|
.
|
Aviiva M4
|
|
.
|
|
.
|
.
|
MEDIUM
|
 |
Tattile S.R.L.
|
TAPIX LCD 2048@9000
|
 |
 |
. |
. |
 |
. |
| . |
. |
TAPIX LCD 8000@14000
|
 |
. |
. |
. |
 |
synchronous operation of trilinear and greyscale sensor in preparation.
|
GigE Vision camera support
Camera compatibility chart (selection of tested cameras) |
|
Area Scan Cameras
|
|
.
|
Company |
Model |
Test Scenario
|
Remarks
|
 |
AVT/Prosilica |
GC655C |
see below |
Bug fix in RT5 |
|
.
|
. |
GC780C |
.see below |
Bug fix in RT5 |
|
.
|
.
|
GE1660 |
see below |
Bug fix in RT5 |
|
.
|
. |
GE1660C |
.see below |
Bug fix in RT5 |
|
.
|
.
|
GE2040C |
see below |
Bug fix in RT5 |
|
.
|
. |
GC750C |
.see below |
. |
|
|
Basler
|
acA640-74gc
|
see below.
|
.
|
|
.
|
. |
piA640-210gm
|
see below.
|
. |
|
.
|
.
|
scA1000-30gm
|
see below
|
.
|
|
.
|
. |
acA750-60gm
|
see below
|
. |
|
Baumer |
TXG50C |
see below |
.
|
|
|
Dalsa
|
Genie HM1400
|
see below
|
.
|
.
|
JAI
|
CB-040-GE
|
see below |
. |
|
.
|
.
|
CB-140-GE
|
see below
|
.
|
|
.
|
. |
CM-030-GE
|
see below |
. |
|
.
|
.
|
CV-A70GE
|
see below
|
.
|
. |
.JAI Pulnix
|
RMC-1405GE
|
see below |
. |
|
.
|
.
|
TMC-4200GE
|
see below
|
.
|
 |
Matrix Vision |
mvBlue Cougar-S121G
|
see below
|
. |
|
.
|
.
|
mvBlue Cougar-X
|
see below
|
.
|
|
.
|
. |
mvBlue Cougar-S120AG
|
see below |
. |
 |
.Mikrotron |
GE b/w (MC1364)
|
see below |
limited frame rate
|
|
.
|
.
|
GE color (MC1365)
|
see below
|
limited frame rate
|
|
.
|
. |
motionBLITZ eosens mini1 |
see below |
. |
|
.
|
.
|
motionBLITZ eosens mini2 |
see below |
.
|
|
.
|
. |
motionBLITZ eosens cube6 |
see below |
. |
|
.
|
.
|
motionBLITZ eosens cube7 |
see below |
.
|
 |
Optronis |
CR450x2 |
siehe unten |
.
|
|
.
|
.
|
CR600x2 |
siehe unten |
.
|
|
.
|
.
|
CR1000x2 |
siehe unten |
.
|
|
.
|
.
|
CR5000x2 |
siehe unten |
.
|
|
|
.Photonfocus
|
MV1-D1312-40-GB
|
see below |
. |
 |
Sony
|
XCG-5005E
|
see below
|
.
|
 |
SVS Vistek |
SVS625MFGE |
see below |
. |
|
.
|
.
|
eco424MVGE |
see below |
.
|
|
Line Scan Camera
|
|
.
|
Company |
Model |
Test Scenario
|
Remarks
|
|
|
Dalsa
|
Spyder 3 SG11 04k80
|
see below
|
.
|
|
.
|
. |
Spyder 3 SG12 02k80 |
see below |
. |
|
|
.
e2v
|
Aviiva UM2 GE4010
|
see below
|
.Bug fix in RT5
|
The compatibility tests cover:
- camera discovery,
- camera configuration via GigE Explorer (random checks) and
- image acquisition (start, stop, restart).
Notes:
- Known Issues will be fixed in a future Runtime (RT) release. Please ask for already available fixes/workarounds
- Customers should use Silicon Software Runtime 5 or higher. Do NOT use Runtime Version 3 or 4
- For some reasons typically the XML interpretation and feature view of the GigE Explorer and a corresponding vendor tool differs on some points
- Tests have been performed on base of certain camera firmware and Runtime version. Silicon Software can not guarantee the compatibility of updated or upgraded camera models or Runtime environments other than tested ones. But we make the effort to keep you up-to-dated. Please ask for a certain environment.
- We would be very happy to get your customer feedback if problems occur with certain camera model s(regardless if it is already listed or not) and also if a certain camera is running successful. Please send an email to support@silicon-software.de
- Your preferred camera is not listed. Please contact us: vertrieb@silicon-software.de
Support of Machine Vision software
| Product |
Company |
Remark |
 |
Common Vision Blox |
Stemmer Imaging
|
current Version 9.1 |
 |
Halcon |
MV Tec
|
current Version 9.x, Visual Applets is supported |
 |
Heurisko |
Aeon Verlag
|
current Version 6 |
 |
LabVIEW |
National Instruments
|
Beta Base Version (evaluation purpose only - on demand) |
Recommendations for operation systems
. |
Driver support |
Products |
Remark |
| Windows XP |
all versions |
Runtime |
32/64bit, service pack 3 recommended |
| Windows XP |
all versions |
VisualApplets |
32bit, service pack 3 recommended |
| Windows Vista |
all versions |
Runtime |
32/64bit, service pack 2 recommended |
| Windows Vista |
all versions |
VisualApplets |
32bit, service pack 2 recommended |
| Windows 7 |
all versions |
Runtime |
32/64bit, preliminary compatibility |
| Windows 7 |
all versions |
VisualApplets |
32bit, preliminary compatibility |
| Linux |
2.6.x |
Runtime |
32/64bit, ask for specific compatibility |
| QNX |
|
Runtime |
6.3.0 Neutrino |
|